calorimetryΒΆ
Path | Dimensions | Type | Units | Description |
---|---|---|---|---|
calorimetry (alpha) | Calometry measurements on various tokamak subsystems | |||
calorimetry.code (alpha) | STRUCTURE | Generic decription of the code-specific parameters for the code that has produced this IDS | ||
calorimetry.code.commit (alpha) | STR_0D | Unique commit reference of software | ||
calorimetry.code.description (alpha) | STR_0D | Short description of the software (type, purpose) | ||
calorimetry.code.library (alpha) | [1...N] | STRUCT_ARRAY | List of external libraries used by the code that has produced this IDS | |
calorimetry.code.library[:].commit (alpha) | STR_0D | Unique commit reference of software | ||
calorimetry.code.library[:].description (alpha) | STR_0D | Short description of the software (type, purpose) | ||
calorimetry.code.library[:].name (alpha) | STR_0D | Name of software | ||
calorimetry.code.library[:].parameters (alpha) | STR_0D | List of the code specific parameters in XML format | ||
calorimetry.code.library[:].repository (alpha) | STR_0D | URL of software repository | ||
calorimetry.code.library[:].version (alpha) | STR_0D | Unique version (tag) of software | ||
calorimetry.code.name (alpha) | STR_0D | Name of software generating IDS | ||
calorimetry.code.output_flag (alpha) | [calorimetry.time] | INT_1D | Output flag : 0 means the run is successful, other values mean some difficulty has been encountered, the exact meaning is then code specific. Negative values mean the result shall not be used. | |
calorimetry.code.parameters (alpha) | STR_0D | List of the code specific parameters in XML format | ||
calorimetry.code.repository (alpha) | STR_0D | URL of software repository | ||
calorimetry.code.version (alpha) | STR_0D | Unique version (tag) of software | ||
calorimetry.cooling_loop (alpha) | [1...N] | STRUCT_ARRAY | Set of cooling loops | |
calorimetry.cooling_loop[:].identifier (alpha) | STR_0D | ID of the loop | ||
calorimetry.cooling_loop[:].mass_flow (alpha) | STRUCTURE | kg.s^-1 | Mass flow of the coolant going through the loop | |
calorimetry.cooling_loop[:].mass_flow.data (alpha) | [calorimetry.cooling_loop[:].mass_flow.time] | FLT_1D (uncertain) | kg.s^-1 | Data |
calorimetry.cooling_loop[:].mass_flow.time (alpha) | [1...N] | FLT_1D_TYPE | s | Time |
calorimetry.cooling_loop[:].mass_flow.validity (alpha) | INT_0D | Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | ||
calorimetry.cooling_loop[:].mass_flow.validity_timed (alpha) | [calorimetry.cooling_loop[:].mass_flow.time] | INT_1D | Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | |
calorimetry.cooling_loop[:].name (alpha) | STR_0D | Name of the loop | ||
calorimetry.cooling_loop[:].temperature_in (alpha) | STRUCTURE | K | Temperature of the coolant when entering the loop | |
calorimetry.cooling_loop[:].temperature_in.data (alpha) | [calorimetry.cooling_loop[:].temperature_in.time] | FLT_1D (uncertain) | K | Data |
calorimetry.cooling_loop[:].temperature_in.time (alpha) | [1...N] | FLT_1D_TYPE | s | Time |
calorimetry.cooling_loop[:].temperature_in.validity (alpha) | INT_0D | Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | ||
calorimetry.cooling_loop[:].temperature_in.validity_timed (alpha) | [calorimetry.cooling_loop[:].temperature_in.time] | INT_1D | Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | |
calorimetry.cooling_loop[:].temperature_out (alpha) | STRUCTURE | K | Temperature of the coolant when exiting the loop | |
calorimetry.cooling_loop[:].temperature_out.data (alpha) | [calorimetry.cooling_loop[:].temperature_out.time] | FLT_1D (uncertain) | K | Data |
calorimetry.cooling_loop[:].temperature_out.time (alpha) | [1...N] | FLT_1D_TYPE | s | Time |
calorimetry.cooling_loop[:].temperature_out.validity (alpha) | INT_0D | Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | ||
calorimetry.cooling_loop[:].temperature_out.validity_timed (alpha) | [calorimetry.cooling_loop[:].temperature_out.time] | INT_1D | Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | |
calorimetry.group (alpha) | [1...N] | STRUCT_ARRAY | Set of groups of components on which calorimetry measurements are carried out (grouped by tokamak subsystems or localisation on the machine) | |
calorimetry.group[:].component (alpha) | [1...N] | STRUCT_ARRAY | Set of components on which calorimetry measurements are carried out | |
calorimetry.group[:].component[:].energy_cumulated (alpha) | STRUCTURE | J | Energy extracted from the component since the start of the pulse | |
calorimetry.group[:].component[:].energy_cumulated.data (alpha) | [calorimetry.group[:].component[:].energy_cumulated.time] | FLT_1D (uncertain) | J | Data |
calorimetry.group[:].component[:].energy_cumulated.time (alpha) | [1...N] | FLT_1D_TYPE | s | Time |
calorimetry.group[:].component[:].energy_cumulated.validity (alpha) | INT_0D | Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | ||
calorimetry.group[:].component[:].energy_cumulated.validity_timed (alpha) | [calorimetry.group[:].component[:].energy_cumulated.time] | INT_1D | Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | |
calorimetry.group[:].component[:].energy_total (alpha) | STRUCTURE | J | Energy extracted from the component on the whole plasma discharge, including the return to thermal equilibrium of the component in the post-pulse phase | |
calorimetry.group[:].component[:].energy_total.data (alpha) | FLT_0D (uncertain) | J | Data | |
calorimetry.group[:].component[:].energy_total.validity (alpha) | INT_0D | Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | ||
calorimetry.group[:].component[:].identifier (alpha) | STR_0D | ID of the component | ||
calorimetry.group[:].component[:].mass_flow (alpha) | STRUCTURE | kg.s^-1 | Mass flow of the coolant going through the component | |
calorimetry.group[:].component[:].mass_flow.data (alpha) | [calorimetry.group[:].component[:].mass_flow.time] | FLT_1D (uncertain) | kg.s^-1 | Data |
calorimetry.group[:].component[:].mass_flow.time (alpha) | [1...N] | FLT_1D_TYPE | s | Time |
calorimetry.group[:].component[:].mass_flow.validity (alpha) | INT_0D | Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | ||
calorimetry.group[:].component[:].mass_flow.validity_timed (alpha) | [calorimetry.group[:].component[:].mass_flow.time] | INT_1D | Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | |
calorimetry.group[:].component[:].name (alpha) | STR_0D | Name of the component | ||
calorimetry.group[:].component[:].power (alpha) | STRUCTURE | W | Power extracted from the component | |
calorimetry.group[:].component[:].power.data (alpha) | [calorimetry.group[:].component[:].power.time] | FLT_1D (uncertain) | W | Data |
calorimetry.group[:].component[:].power.time (alpha) | [1...N] | FLT_1D_TYPE | s | Time |
calorimetry.group[:].component[:].power.validity (alpha) | INT_0D | Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | ||
calorimetry.group[:].component[:].power.validity_timed (alpha) | [calorimetry.group[:].component[:].power.time] | INT_1D | Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | |
calorimetry.group[:].component[:].temperature_in (alpha) | STRUCTURE | K | Temperature of the coolant when entering the component | |
calorimetry.group[:].component[:].temperature_in.data (alpha) | [calorimetry.group[:].component[:].temperature_in.time] | FLT_1D (uncertain) | K | Data |
calorimetry.group[:].component[:].temperature_in.time (alpha) | [1...N] | FLT_1D_TYPE | s | Time |
calorimetry.group[:].component[:].temperature_in.validity (alpha) | INT_0D | Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | ||
calorimetry.group[:].component[:].temperature_in.validity_timed (alpha) | [calorimetry.group[:].component[:].temperature_in.time] | INT_1D | Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | |
calorimetry.group[:].component[:].temperature_out (alpha) | STRUCTURE | K | Temperature of the coolant when exiting the component | |
calorimetry.group[:].component[:].temperature_out.data (alpha) | [calorimetry.group[:].component[:].temperature_out.time] | FLT_1D (uncertain) | K | Data |
calorimetry.group[:].component[:].temperature_out.time (alpha) | [1...N] | FLT_1D_TYPE | s | Time |
calorimetry.group[:].component[:].temperature_out.validity (alpha) | INT_0D | Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | ||
calorimetry.group[:].component[:].temperature_out.validity_timed (alpha) | [calorimetry.group[:].component[:].temperature_out.time] | INT_1D | Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | |
calorimetry.group[:].component[:].transit_time (alpha) | STRUCTURE | s | Transit time for the coolant to go from the input to the output of the component | |
calorimetry.group[:].component[:].transit_time.data (alpha) | [calorimetry.group[:].component[:].transit_time.time] | FLT_1D (uncertain) | s | Data |
calorimetry.group[:].component[:].transit_time.time (alpha) | [1...N] | FLT_1D_TYPE | s | Time |
calorimetry.group[:].component[:].transit_time.validity (alpha) | INT_0D | Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | ||
calorimetry.group[:].component[:].transit_time.validity_timed (alpha) | [calorimetry.group[:].component[:].transit_time.time] | INT_1D | Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity) | |
calorimetry.group[:].identifier (alpha) | STR_0D | ID of the group | ||
calorimetry.group[:].name (alpha) | STR_0D | Name of the group | ||
calorimetry.ids_properties (alpha) | STRUCTURE | Interface Data Structure properties. This element identifies the node above as an IDS | ||
calorimetry.ids_properties.comment (alpha) | STR_0D | Any comment describing the content of this IDS | ||
calorimetry.ids_properties.creation_date (alpha) | STR_0D | Date at which this data has been produced | ||
calorimetry.ids_properties.homogeneous_time (alpha) | INT_0D | This node must be filled (with 0, 1, or 2) for the IDS to be valid. If 1, the time of this IDS is homogeneous, i.e. the time values for this IDS are stored in the time node just below the root of this IDS. If 0, the time values are stored in the various time fields at lower levels in the tree. In the case only constant or static nodes are filled within the IDS, homogeneous_time must be set to 2 | ||
calorimetry.ids_properties.name (alpha) | STR_0D | User-defined name for this IDS occurrence | ||
calorimetry.ids_properties.occurrence | INT_0D | |||
calorimetry.ids_properties.occurrence_type (alpha) | STRUCTURE | Type of data contained in this occurrence | ||
calorimetry.ids_properties.occurrence_type.description (alpha) | STR_0D | Verbose description | ||
calorimetry.ids_properties.occurrence_type.index (alpha) | INT_0D | Integer identifier (enumeration index within a list). Private identifier values must be indicated by a negative index. | ||
calorimetry.ids_properties.occurrence_type.name (alpha) | STR_0D | Short string identifier | ||
calorimetry.ids_properties.plugins (alpha) | STRUCTURE | Information about the plugins used to write/read this IDS. This structure is filled automatically by the Access Layer at GET/PUT time, no need to fill it via a user program. | ||
calorimetry.ids_properties.plugins.infrastructure_get (alpha) | STRUCTURE | Plugin infrastructure used to GET the data | ||
calorimetry.ids_properties.plugins.infrastructure_get.commit (alpha) | STR_0D | Unique commit reference of software | ||
calorimetry.ids_properties.plugins.infrastructure_get.description (alpha) | STR_0D | Short description of the software (type, purpose) | ||
calorimetry.ids_properties.plugins.infrastructure_get.name (alpha) | STR_0D | Name of software used | ||
calorimetry.ids_properties.plugins.infrastructure_get.repository (alpha) | STR_0D | URL of software repository | ||
calorimetry.ids_properties.plugins.infrastructure_get.version (alpha) | STR_0D | Unique version (tag) of software | ||
calorimetry.ids_properties.plugins.infrastructure_put (alpha) | STRUCTURE | Plugin infrastructure used to PUT the data | ||
calorimetry.ids_properties.plugins.infrastructure_put.commit (alpha) | STR_0D | Unique commit reference of software | ||
calorimetry.ids_properties.plugins.infrastructure_put.description (alpha) | STR_0D | Short description of the software (type, purpose) | ||
calorimetry.ids_properties.plugins.infrastructure_put.name (alpha) | STR_0D | Name of software used | ||
calorimetry.ids_properties.plugins.infrastructure_put.repository (alpha) | STR_0D | URL of software repository | ||
calorimetry.ids_properties.plugins.infrastructure_put.version (alpha) | STR_0D | Unique version (tag) of software | ||
calorimetry.ids_properties.plugins.node (alpha) | [1...N] | STRUCT_ARRAY | Set of IDS nodes for which a plugin has been applied | |
calorimetry.ids_properties.plugins.node[:].get_operation (alpha) | [1...N] | STRUCT_ARRAY | Plugins actually used to read back a node (potentially, multiple plugins can be applied, listed in reverse order of application). This information is filled by the plugin infrastructure during the GET operation. | |
calorimetry.ids_properties.plugins.node[:].get_operation[:].commit (alpha) | STR_0D | Unique commit reference of software | ||
calorimetry.ids_properties.plugins.node[:].get_operation[:].description (alpha) | STR_0D | Short description of the software (type, purpose) | ||
calorimetry.ids_properties.plugins.node[:].get_operation[:].name (alpha) | STR_0D | Name of software used | ||
calorimetry.ids_properties.plugins.node[:].get_operation[:].parameters (alpha) | STR_0D | List of the code specific parameters in XML format | ||
calorimetry.ids_properties.plugins.node[:].get_operation[:].repository (alpha) | STR_0D | URL of software repository | ||
calorimetry.ids_properties.plugins.node[:].get_operation[:].version (alpha) | STR_0D | Unique version (tag) of software | ||
calorimetry.ids_properties.plugins.node[:].path (alpha) | STR_0D | Path of the node within the IDS, following the syntax given in the link below. If empty, means the plugin applies to the whole IDS. | ||
calorimetry.ids_properties.plugins.node[:].put_operation (alpha) | [1...N] | STRUCT_ARRAY | Plugins used to PUT a node (potentially, multiple plugins can be applied, if so they are listed by order of application) | |
calorimetry.ids_properties.plugins.node[:].put_operation[:].commit (alpha) | STR_0D | Unique commit reference of software | ||
calorimetry.ids_properties.plugins.node[:].put_operation[:].description (alpha) | STR_0D | Short description of the software (type, purpose) | ||
calorimetry.ids_properties.plugins.node[:].put_operation[:].name (alpha) | STR_0D | Name of software used | ||
calorimetry.ids_properties.plugins.node[:].put_operation[:].parameters (alpha) | STR_0D | List of the code specific parameters in XML format | ||
calorimetry.ids_properties.plugins.node[:].put_operation[:].repository (alpha) | STR_0D | URL of software repository | ||
calorimetry.ids_properties.plugins.node[:].put_operation[:].version (alpha) | STR_0D | Unique version (tag) of software | ||
calorimetry.ids_properties.plugins.node[:].readback (alpha) | [1...N] | STRUCT_ARRAY | Plugins to be used to read back a node (potentially, multiple plugins can be applied, listed in reverse order of application) | |
calorimetry.ids_properties.plugins.node[:].readback[:].commit (alpha) | STR_0D | Unique commit reference of software | ||
calorimetry.ids_properties.plugins.node[:].readback[:].description (alpha) | STR_0D | Short description of the software (type, purpose) | ||
calorimetry.ids_properties.plugins.node[:].readback[:].name (alpha) | STR_0D | Name of software used | ||
calorimetry.ids_properties.plugins.node[:].readback[:].parameters (alpha) | STR_0D | List of the code specific parameters in XML format | ||
calorimetry.ids_properties.plugins.node[:].readback[:].repository (alpha) | STR_0D | URL of software repository | ||
calorimetry.ids_properties.plugins.node[:].readback[:].version (alpha) | STR_0D | Unique version (tag) of software | ||
calorimetry.ids_properties.provenance (alpha) | STRUCTURE | Provenance information about this IDS | ||
calorimetry.ids_properties.provenance.node (alpha) | [1...N] | STRUCT_ARRAY | Set of IDS nodes for which the provenance is given. The provenance information applies to the whole structure below the IDS node. For documenting provenance information for the whole IDS, set the size of this array of structure to 1 and leave the child "path" node empty | |
calorimetry.ids_properties.provenance.node[:].path (alpha) | STR_0D | Path of the node within the IDS, following the syntax given in the link below. If empty, means the provenance information applies to the whole IDS. | ||
calorimetry.ids_properties.provenance.node[:].sources (alpha) | [1...N] | STR_1D | List of sources used to import or calculate this node, identified as explained below. In case the node is the result of of a calculation / data processing, the source is an input to the process described in the "code" structure at the root of the IDS. The source can be an IDS (identified by a URI or a persitent identifier, see syntax in the link below) or non-IDS data imported directly from an non-IMAS database (identified by the command used to import the source, or the persistent identifier of the data source). Often data are obtained by a chain of processes, however only the last process input are recorded here. The full chain of provenance has then to be reconstructed recursively from the provenance information contained in the data sources. | |
calorimetry.ids_properties.provider (alpha) | STR_0D | Name of the person in charge of producing this data | ||
calorimetry.ids_properties.source (obsolescent) | STR_0D | Source of the data (any comment describing the origin of the data : code, path to diagnostic signals, processing method, ...). Superseeded by the new provenance structure. | ||
calorimetry.ids_properties.version_put (alpha) | STRUCTURE | Version of the access layer package used to PUT this IDS | ||
calorimetry.ids_properties.version_put.access_layer (alpha) | STR_0D | Version of Access Layer used to PUT this IDS | ||
calorimetry.ids_properties.version_put.access_layer_language (alpha) | STR_0D | Programming language of the Access Layer high level API used to PUT this IDS | ||
calorimetry.ids_properties.version_put.data_dictionary (alpha) | STR_0D | Version of Data Dictionary used to PUT this IDS | ||
calorimetry.latency (alpha) | FLT_0D (uncertain) | s | Upper bound of the delay between physical information received by the detector and data available on the real-time (RT) network. | |
calorimetry.time (alpha) | [1...N] | FLT_1D_TYPE | s | Generic time |